Tuesday, March 12, 2019
Compare & Contrats: Lineman Terms
In the electrical construction business, motive companies tail end choose whether to mathematical function asserters or their deliver liveers to eject a job. They es moveial(prenominal) consider the size of the job and cartridge clip frame they feed to complete the job. The take on habits of contain aviationmen and gallium agency alliance linemen play a large part in the finality of which company will be the best to complete the job. Line human commit heavy equipment to complete their jobs. An aerial bucketful is a truck that has a fiberglass boom, a long scissor like arm, with an isolated bucket attached so that linemen fire practice it to reach energized electrical lines. about of these buckets have a special fiberglass arm at the residual of the boom with a roller on it, c whollyed a jib, which uses a force to lift heavy objects up to one thousand pounds, called material handlers. Contractors use a two man material handling bucket. Due to unappeasable r ules about work two conductors at the similar duration, Georgia berth linesman crowd outt work out of a two man bucket so they use a single man material handling truck. The next piece of equipment used by a electrician is a line truck. It has an auger attached to the boom that diggings deep holes for the pole to be set.This truck also sets the pole and plunder lift heavy objects with its winch line, similar to how a crane works. The exactors truck has a center mounted boom, which has a undersurface mounted at the base on the boom. This truck can work the same strength from either side of the truck. Unlike the contractors truck, the Georgia Power linesmans truck is a recess mounted boom, which is located on the rear passenger side of the truck. It has a farther reach off of the passenger side of the truck, but it is not as strong on the driver side of the truck.These trucks have to rive trailers behind them to incline poles virtually. A contract linesman uses a xxx foot pole trailer which is the standard size used to haul around a large number of poles. The follow linesman uses a material trailer that is about fifteen foot long with boxes on the side to hold wire and materials. When they need to haul a pole, the spit can be extended out to the length needed. This trailer can only haul about five poles at max. Although they use polar trucks, the trucks joysticks and levers all have the same functions.One of the study similarities between a contractor and a Georgia Power lineman is that they both have to follow rules and regulations from the Occupational Safety and Health institution and the National Electrical Safety Code standards. They both have to prevail a harness when running(a) out of the bucket, and wear a organic structure belt, has two d-rings placed at the hips that you attach a strap to, when they ar six feet off the ground on a pole or ladder. Both types of lineman must wear rubber gloves while working in the bucket that pas s across hand up to the elbow.A contractor wears class three rubber gloves. They are rated for thirty thousand volts. work on the same line, a Georgia Power lineman can wear class two gloves that are rated for twenty thousand volts. The campaign for the difference in standards is the amount of administer-up used, which is another way linemen blockage protected while working on electrical wires. It is called this because they use it to cover the energized lines. Cover-up is orange colored so that the linemen can easily devour it and it comes in many forms.The contract linemen and community linemen use hoses, blankets, and hoods to cover-up the spring lines. A hose, sometimes called an eel, is six feet long and slides over the wire to cover around it. A blanket is a four foot whole that is used to wrap around the pole, its arms, or insulators. A hood is pre-formed to give out insulators perfectly, but not all linemen use them because they take up as well much space on the tru ck. A contactor does not use the same amount of cover-up as a Georgia Power lineman would. Company linemen have a four step cover-up procedure.First, they must cover the conductors in the order they come to them. Second, before uncovering an energized conductor, all paths to ground must be covered. A ground is anything that an electric on-going can use to get back to the earth from the wire. Third, before working on a grounded component, all energized conductors must be covered. Last, the cover-up must be removed in the order it was placed. It makes for a little more than work for the company lineman, but it keeps them from having to wear rubber sleeves.Unlike the company lineman, a contractor must wear rubber sleeves which start at the top of the shoulder and covers down to the wrist because they dont use the four rules of cover-up. When the trucks are in an area of energized lines, a contract lineman always has to ground their truck to the pole ground. The truck ground is a copp er wire that ties the truck through the pole ground to the governing body neutral to protect from accidental electrical charge.A power company lineman only has to ground their truck when setting oles and only if in that location is a chance of an accidental contact to the truck due to a broken insulator or pole. Contractors must do a weed of departing in order to keep their job they dont have a set location to work from. At the power company, a lineman apprehensions at the same headquarters during his career. Since the lineman is at home, the company calls him to work for local power outages. When major hurricanes expose the coast lines, tornados blow remote cities, or blizzards freeze a fate town, both types of linemen can be asked to help restore power to these communities.When a contractor goes out of town, his crew will be the only ones that work together during the restoration. They will meet up with fellow contract lineman only for meals and meetings. As a Georgia Powe r lineman, you are sent out with your whole region. A caravan of trucks and vans leave the headquarters and travel to their destination together to help restore power to the area. There are also support members from inside the office that travel with the aggroup. While away from home, contract linemen either nap in a hotel or, on occasion, balance inside their trucks.The power company linemen have a support team to make sure they get a level-headed place to sleep every night while on the storm group. So the likelihood of having to sleep in their trucks is slim to none. The quality of work differs between the contract lineman and a Georgia Power lineman. A contract lineman bids on the job and gets paid per task they complete. Because speed equals money, a contract lineman tends to rush through work to finish faster. Because he is rushed, the possibly work is unsatisfactory to trained company lineman.Contractors have a saying, It looks good to me. You cant see it from my house. A company lineman can take his time and do his job safely and this reflects in his work. He takes pride in his work because he can ride around his community and look at project he has worked on. I bop firsthand the work habits of a contract lineman and a Georgia Power Company lineman. I worked for contractors for five years before I was hired by the power company. After many years of line experience, I have noticed that my work and safety habits improved after becoming a company lineman.Even though both types of linemen have the same profession, they approach the job in different ways to complete it. A power company chooses contractors over company linemen when it is necessary to stay devoted to a single job they are working on. Company linemen have the responsibility of responding to power outages, and this extends the time it takes to complete the job. The pros and cons of both types of linemen and the time it takes to complete the job are the two major factors that are interpret ed into consideration by Georgia Power Company when deciding which group will be assigned to the job.
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.